[SOURce]:ILS:LOC[:STATe]?
This command enables or disables the ILS localizer modulation.
*RST OFF
:ILS:LOCalizer:AM0[:DEPTh]
[SOURce]:ILS:LOCalizer:AM0[:DEPTh] <value>
[SOURce]:ILS:LOCalizer:AM0[:DEPTh]?
This command sets the 90 Hz localizer amplitude modulation depth.
*RST 0.2
:ILS:LOCalizer:AM1[:DEPTh]
[SOURce]:ILS:LOCalizer:AM1[:DEPTh] <value>
[SOURce]:ILS:LOCalizer:AM1[:DEPTh]?
This command sets the 150 Hz localizer amplitude modulation depth.
*RST 0.2
:ILS:LOC:TEST
[SOURce]:ILS:LOC:TEST DDM0|LEFT|RIGHT|FLAG
This command selects a predefined ILS localizer test setting.
*RST DDM0