Bnc 1621M Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Instruments de mesure Bnc 1621M. BNC 1621M User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 27
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1621M OPERATING MANUAL
1621M OPERATING MANUAL
palmRAD Model
palmRAD Model
1621M
h o s p i t a l s n u c l e a r p o w e r p l a n t s l a b s H A Z M AT w a s t e p r o c e s s i n g h o s p i t a l s nuclear power plants labs HAZMAT waste processing hospitals nuclear power plants labs HAZMAT waste processing
Vue de la page 0
1 2 3 4 5 6 ... 26 27

Résumé du contenu

Page 1 - 1621M OPERATING MANUAL

1621M OPERATING MANUAL 1621M OPERATING MANUALpalmRAD Model palmRAD Model 1621Mh o s p i t a l s • n u c l e a r p o w e r p l a n t s • l

Page 2

2 USE OF THE DOSIMETER2.1 General GuidelinesWhen you receive the device after purchase please check the delivery kit and con rm proper operation of t

Page 3 - 2

1621M OPERATING MANUAL2.4 Use of the Dosimeter2.4.1 The dosimeter operates in the following modes:• Photon radiation DER indication mode;• Photon radi

Page 4 - Operating Conditions:

Standard con guration of the dosimeter as shipped includes the following parameters and functions:DER Indication Mode - OnFigure 1.2, Item 2DER value

Page 5 - INSTRUMENT SPECIFICATIONS:

1621M OPERATING MANUAL2.4.2 Selection of an Indicated ParameterDER, DE, dosimeter’s number and data transmission to PC modes are switched on by a succ

Page 6

2.4.3 DER Indication ModeIn the DER mode (Figure 2.1) the following values appear on the LCD:• DER (µR/h, mR/h, R/h);• DER on the analog scale in a lo

Page 7

1621M OPERATING MANUALThe second method. The dose value in the beginning of the period of measurement should be deducted from the DE value

Page 8

2.4.5 Set modeAuxiliary set mode (Figures 2.2 and 2.3) is meant for veri cation and (or) setting of the threshold DE (DER) values, DE and DE accumula

Page 9

1621M OPERATING MANUAL2.4.6 Number Indication ModeIn number indication mode, the following items appear on the LCD:• The dosimeter’s number on a displ

Page 10 - 2 USE OF THE DOSIMETER

To use the dosimeter in data transmission to PC mode:• Read and follow the recommendations of the  le Read_me.doc on the CD supplied with IR adapte

Page 11 - 1621M OPERATING MANUAL

1621M OPERATING MANUAL2. Read-out of the following information from dosimeter to PC:• Dosimeter’s parameters;• DER history and DE accumulation (date,

Page 12 - Number Indication Mode - On

h o s p i t a l s • n u c l e a r p o w e r p l a n t s • l a b s • H A Z M AT • w a s t e p r o c e s s i n g • h o s p

Page 13

19Figure 2.3 – Setting the DER threshold values

Page 14 - 2.4.4 DE Indication Mode

1621M OPERATING MANUAL3. MAINTENANCE3.1 Maintenance involves preventive services, battery replacement and a regular performance check (according to 2.

Page 15

4. TROUBLESHOOTINGThe list of possible problems and their solutions are speci ed in Table 4.15. STORAGE AND SHIPPING5.1. Packaged devices may be ship

Page 16 - 2.4.5 Set mode

1621M OPERATING MANUAL6. WARRANTY6.1. Berkeley Nucleonics Corporation warrants all instruments, including component parts, to be free from defect

Page 18

1621M OPERATING MANUAL 24

Page 19

Anisotropy of the device for each energy does not exceed values (in %) presented in Table 1.1, when the device is rotated in the horizontal plane (App

Page 20

1621M OPERATING MANUAL2955 KERNER BLVD. SAN RAFAEL, CA 94901 • TEL 415.453.9955 • FAX [email protected] • WWW.BE RKELEYNUC

Page 21 - 20

1621M OPERATING MANUALDESCRIPTION & OPERATION OF THE DOSIMETER1.1 Application of the dosimeterThe 1621M X-ray and gamma radiation dosimeter is des

Page 22 - 5. STORAGE AND SHIPPING

Dosimeters may be used independently or as a part of a system for everyday, ef cient and emergency dosimetric control of personnel, production facili

Page 23 - 6. WARRANTY

1621M OPERATING MANUALFor additional technical speci cations about the dosimeter, please visit www.BerkeleyNucleonics.com.INSTRUMENT SPECIFICATIONS:

Page 24

1.4 Design and theory of operation 1.4.1 The dosimeter is comprised of the following main blocks and modules: radiation detector; microprocessor; LCD;

Page 25

1621M OPERATING MANUAL1.4.2 The device is housed in a plastic shock-proof case. A general overview of the dosimeter and its parts is shown in Figure 1

Page 26

1. DER analog scale (seven segments) for quick visual status of radiation situation;2.DER digital panel in DER indication mode, DE in DE indication mo

Page 27

1621M OPERATING MANUALThe dosimeter’s operating algorithm ensures continuity of the measurement process, statistical processing of the measurement res