Bnc 835-3 Programmer Manual Manuel d'utilisateur Page 25

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 37
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 24
Berkeley Nucleonics
www.Berkeley Nucleonics.com
835-3
Programmer’s Manual v1.0
Page 25 of 37
:LFOutput:AMPLitude
[SOURce]:LFOutput:AMPLitude <value>
[SOURce]:LFOutput:AMPLitude?
This command sets the low frequency generator amplitude. This setting does only take
effect if :LFOutput:SOURce is set to LFGenerator and LFOutput:SHAPe is either set to
SINE or TRIangle. Using any other setting, the output amplitude is fixed 2.5 V.
The variable <value> is expressed in units of Volt.
Range 0-2.5
*RST 1
:LFOutput:FREQuency
[SOURce]:LFOutput:FREQuency <value>
[SOURce]:LFOutput:FREQuency?
This command sets the low frequency generator frequency. This setting does only take
effect if :LFOutput:SOURce is set to LFGenerator.
The variable <value> is expressed in units of Hertz.
Range 10-5000000
*RST 400
:LFOutput:STATe
[SOURce]:LFOutput:STATe ON|OFF|1|0
[SOURce]:LFOutput:STATe?
This command sets the function output / low frequency generator state.
*RST OFF
:LFOutput:SHAPe
[SOURce]:LFOutput:SHAPe SINE|TRIangle|SQUare
[SOURce]:LFOutput:SHAPe?
This command sets the low frequency generator waveform. This setting does only take
effect if :LFOutput:SOURce is set to LFGenerator.
SINE Sine wave output, amplitude is selectable by the :LFOutput:AMPLitude
setting.
TRIangle Triangle wave output, amplitude is selectable by the :LFOutput:AMPLitude
setting.
SQUare Square wave output, amplitude is fixed 2.5 V.
*RST SINE
:LFOutput:SOURce
[SOURce]:LFOutput:SOURce LFGenerator|PULM|TRIGger
[SOURce]:LFOutput:SOURce?
This command sets the low frequency generator waveform. This setting does only take
effect if :LFOutput:SOURce is set to LFGenerator.
LFGenerator This selects the low frequency generator as the function output signal.
PULM This selects the pulse modulation video out as the function output signal.
TRIGger This selects the trigger as the function output signal.
*RST LFG
[SOURce]:SWEep Subsystem
Command Parameters